Filter Results By:

Products

Applications

Manufacturers

Showing results: 1906 - 1920 of 2604 items found.

  • PWM Type AC Power Supply

    LSP-5KVA - Lisun Electronics Inc.

    • Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is  0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter  Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%

  • DC Power Source for Standard Lamp

    DC502 - Lisun Electronics Inc.

    DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA

  • Milliohm Meter

    16502 - Chroma Systems Solutions, Inc.

    Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface

  • PXIe-4154, 2-Channel, 8 V, 3 A PXI Programmable Power Supply

    781155-01 - NI

    2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.

  • Programmable AC Power Source

    LSP-500VAC - Lisun Electronics Inc.

    • Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);

  • Micro - Ohmmeter / Milli - Ohmmeter

    Meco Instruments Pvt. Ltd.,

    Basic Accuracy 0.25%Max. Test Current : 5A (120mV) for 7002Max. Test Current : 10A (60mV) for 7272Manual or Auto RangeFour Terminal Kelvin Measurement6 Ranges with 1mV Best ResolutionMeasurement of Resistive and Inductive MaterialsSetting for HI, LO & PASS ReadingsMemory of 3000 Measurements DataProgrammable HI-LO Alarm with memory of 20 DataLarge LCD with Backlight & HOLD FunctionLow Power ConsumptionBattery Operated with AC AdaptorLow Battery (Voltage) AlarmLED indication for Invalid Resistance MeasurementCable Length Measurement in feet & metersUser Interface Software for PC Communication via RS232C(to USB Bridge) cableBuilt-inBatery Chaging Circuit & Calender Clock

  • 1000A AC Clamp Meter with IR Thermometer

    Extech EX810 - Extech Instruments Corporation

    The EX810 Clamp meter features a built-in IR thermometer with laser pointer for non-contact surface measurements from -58 to 518 degrees Fahrenheit (-50 to 270 degrees Celsius). Clamp measures AC current up to 1000 Amp with a maximum resolution of 0.1 Amp. The 1.7 in. jaw fits around conductors up to 750MCM. Peak hold captures motor inrush currents and other surges. Data hold and auto power off functions. Other features include AC/DC voltage, resistance, capacitance and frequency. Complete with test leads, 9 Volt battery and case.

  • Power Supply

    EXC-PSM104P85S - Excalibur Systems, Inc.

    The EXC-PSM104P85S is an isolated DC power supply specifically designed to provide reliable power for highly demanding PC104-Plus imbedded applications. The EXC-PSM104P85S has a wide input voltage range while providing robust and reliable power for embedded and industrial motherboards. The power supply is also fully compliant with MIL-STD-704A and E, MIL-STD-1275B and MIL-STD-461E.The EXC- PSM104P85S has totally independent safety features including input undervoltage lock-out, output overvoltage protection, output current limit protection, and temperature protection. Additionally, the Soft-Start function limits inrush current during startup.

  • Isolated DC Power Supply for PC104-PCI Express Embedded Applications

    EXC-PSM104PCIe - Excalibur Systems, Inc.

    The EXC-PSM104PCIe is an isolated DC power supply specifically designed to provide reliable power for highly demanding PC104-PCI Express embedded applications. The EXC-PSM104PCIe has a wide input voltage range while providing robust and reliable power for embedded and industrial motherboards. The power supply is also fully compliant with MIL-STD-704A and E, MIL-STD-1275B and MIL-STD-461E.The EXC- PSM104PCIe has totally independent safety features including input undervoltage lock-out, output overvoltage protection, output current limit protection, and temperature protection. Additionally, the Soft-Start function limits inrush current during startup.

  • 8 Function True RMS Professional MultiMeter

    Extech EX411A - Extech Instruments Corporation

    The EX411A offers multiple functions so you can carry one meter into the field instead of several. The manual-ranging EX411A measures AC/DC voltage, AC/DC current, resistance, diode, and continuity, all with +/-0.5 percent basic accuracy. The unit has low current capability, measuring down to 0.1uA, and features input fuse protection and mis-connection warnings. A Type K thermometer is built in for surface or air temperature measurements. Comes with CAT III test leads, stand, hanging strap, holster with built-in test lead storage, Type K bead wire temperature probe, and battery.

  • Common Mode Chokes

    Pulse Electronics

    Common Mode Chokes, as the name implies, are designed to attenuate and filter common mode noise within an electric system.   The key parameters for a common mode choke are the current rating (to ensure the part does not overheat within the application), the impedance versus frequency (to ensure it is optimized to attenuate the desired frequencies), the isolation voltage (to ensure it meets board level requirements between the line and neutral phases) and safety isolation (to ensure it meets the safety requirements of the end-application).   It is important to remember that common mode chokes cannot saturate in the application (under normal use) as they are designed to ensure that the line and return currents are balanced.

  • Leakage Current Clamp Mete

    Nanjing ELIKE Meter Co, Ltd.

    Basic functions:AC current:20mA resolution: 0.01mA, ± (2.5%, +5)200mA resolution: 0.1mA, ±(2.5%, +5)2A resolution: 1mA, ±(2.5%, +5)60A resolution: 100mA, ±(3%, +8)AC voltage: 600V, ±(0.8%, +5)DC voltage: 600V, ±(0.8%, +5)Special functions:Auto ranging Low battery display Data hold Auto power-off Over-load protection Input impedanceDC voltage measurement: ≥10MΩ Sampling frequency: 3 times/s Maximum display: 1999 Maximum distance between clamps: 30mm General characteristics:Product colors: iron-gray and redProduct net weight: approximately 136gLCD size: 25x36mmProduct size: 183x63x29mmPower: 2x1.5V, 7#Standard accessories: packing carton and handheld bag English user's manual and battery

  • Controllable, Programmable Linear DC Source With Load

    LAB / SLR - ET System Electronic GmbH

    *Linear laboratory power supply*Integrated electronic load*Automatic range selection*Linear regulated DC source with automatic range selection*Built-in electronic load*Short-term peak load operation 240 or 480 watts*Protection against short circuit, overload and overtemperature*Double current / double voltage through "autoranging"*Fast control times approx. 250µ

  • Digital Multimeter

    DMT 2004 - Monacor International GmbH & Co. KG

    *2000 digit resolution*Voltage measurement up to DC/˜ 250 V*Current measurement up to DC/˜ 10 A*Resistance measurement up to 2 MΩ*Battery test for 9V block and 1.5V cells*Acoustic continuity test*diode test*Data hold (measured value memory)*LC display with switchable background lighting*overload protection*Supplied with test leads

  • High-Voltage Power Amplifier

    Model PZD2000A - TREK, INC.

    The Trek Model PZD2000A is a wide bandwidth high-voltage power amplifier used for precision high power applications. This new addition to the Trek power amplifier product line is designed to provide precise control of output voltages in the range of 0 to ±2 kV DC. Features include an output current range of 0 to ±400 mA and an excellent large signal bandwidth capability.